<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15052</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: autoloader operation timed out
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
An autloader action is timing out before completion.  The solution
depends on which specific incidence is causing this error to be generated.
Analyze the diagnostic output and see if the operation which is timing out
is apparent.  If so, attempt to find out why the operation is
timing out.  If this proves impossible, capture a log file of the error
from diagnostic monitor and contact the product's TTE.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Select Resume if that option is available.  If the error persists, try
powering the machine off and back on again.  If the problem still
persists, call Creo service.
</text></DescriptionText>
</OperatorAction>
<Cause>
This error indicates that an autoloader action (Stepper driver) has timed out.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/altim_cfg_yhome.xml</LinkAddress><LinkTitle>NVS: altim yhome</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:49 2008 PST
</Updated>